答复: [chrony-users] Multiple Clock Sources Cannot Be Synchronized

[ Thread Index | Date Index | More chrony.tuxfamily.org/chrony-users Archives ]


Thank you for your reply. There is another question. What is the difference between two clock sources to make them trust each other? After all, the difference of 65 ms can be ignored in some scenarios.
-----邮件原件-----
发件人: Miroslav Lichvar <mlichvar@xxxxxxxxxx> 
发送时间: 2024年10月24日 21:29
收件人: chrony-users@xxxxxxxxxxxxxxxxxxxx
主题: Re: [chrony-users] Multiple Clock Sources Cannot Be Synchronized

On Thu, Oct 24, 2024 at 01:02:40PM +0000, chengyechun wrote:
> MS Name/IP address         Stratum Poll Reach LastRx Last sample
> 
> ======================================================================
> =========
> 
> ^x 9.82.178.244                 10   2    17     1  +3788ns[+3788ns] +/-  147us
> 
> ^x 9.82.165.239                 10   2    17     1    -65ms[  -65ms] +/-  152us

These two sources don't agree with each other. They are about 65 milliseconds apart. chronyd doesn't know which one (if any) is correct. That's why normally is recommended to have at least three sources. You can mark one with the "trust" option to force chronyd to select it.

--
Miroslav Lichvar


-- 
To unsubscribe email chrony-users-request@xxxxxxxxxxxxxxxxxxxx 
with "unsubscribe" in the subject.
For help email chrony-users-request@xxxxxxxxxxxxxxxxxxxx 
with "help" in the subject.
Trouble?  Email listmaster@xxxxxxxxxxxxxxxxxxxx.