Re: [chrony-users] Multiple Clock Sources Cannot Be Synchronized

[ Thread Index | Date Index | More chrony.tuxfamily.org/chrony-users Archives ]


On Thu, Oct 24, 2024 at 01:02:40PM +0000, chengyechun wrote:
> MS Name/IP address         Stratum Poll Reach LastRx Last sample
> 
> ===============================================================================
> 
> ^x 9.82.178.244                 10   2    17     1  +3788ns[+3788ns] +/-  147us
> 
> ^x 9.82.165.239                 10   2    17     1    -65ms[  -65ms] +/-  152us

These two sources don't agree with each other. They are about 65
milliseconds apart. chronyd doesn't know which one (if any) is
correct. That's why normally is recommended to have at least three
sources. You can mark one with the "trust" option to force chronyd to
select it.

-- 
Miroslav Lichvar


-- 
To unsubscribe email chrony-users-request@xxxxxxxxxxxxxxxxxxxx 
with "unsubscribe" in the subject.
For help email chrony-users-request@xxxxxxxxxxxxxxxxxxxx 
with "help" in the subject.
Trouble?  Email listmaster@xxxxxxxxxxxxxxxxxxxx.


Mail converted by MHonArc 2.6.19+ http://listengine.tuxfamily.org/