Re: [chrony-users] Using cellular network clock as refclock in chrony |
[ Thread Index |
Date Index
| More chrony.tuxfamily.org/chrony-users Archives
]
- To: chrony-users@xxxxxxxxxxxxxxxxxxxx
- Subject: Re: [chrony-users] Using cellular network clock as refclock in chrony
- From: Miroslav Lichvar <mlichvar@xxxxxxxxxx>
- Date: Wed, 31 Jul 2024 10:52:08 +0200
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=redhat.com; s=mimecast20190719; t=1722415936; h=from:from:reply-to:subject:subject:date:date:message-id:message-id: to:to:cc:mime-version:mime-version:content-type:content-type: in-reply-to:in-reply-to:references:references; bh=/h5qFv73akFUUdLNGnnySJi4GTUr1LjBeO1l/rF0nAQ=; b=STBddGWqBnNK0C8fN4BSgjpSxxj0L2wyC7jc3Doc1v8FYTditZyH6fY4gFsc5Pi7D5rLKK btnNdDUyWOf/WhmcvE7PknbLTVXkARlNgtVIy/GJyr80W9FSYeQ8OAhLP1TZZfAdjcOlrI V2KT4fd6cZe1ba61wVH5WHUiI2osazI=
On Wed, Jul 31, 2024 at 08:42:52AM +0000, Amol Lad wrote:
> refclock SOCK /var/run/chrony.cellular.sock precision 1 prefer poll 3 refid MODM
>
> (I tried reducing the poll to 1 but this does not seem to make any difference)
Try adding "filter 1" to reduce the number of samples required per
poll. Unlike with SHM, chronyd doesn't know how many SOCK samples
there will be per poll, so it doesn't adjust the filter length
automatically.
--
Miroslav Lichvar
--
To unsubscribe email chrony-users-request@xxxxxxxxxxxxxxxxxxxx
with "unsubscribe" in the subject.
For help email chrony-users-request@xxxxxxxxxxxxxxxxxxxx
with "help" in the subject.