-----邮件原件-----
发件人: Miroslav Lichvar [mailto:mlichvar@xxxxxxxxxx]
发送时间: 2022年11月28日 16:47
收件人: chrony-users@xxxxxxxxxxxxxxxxxxxx
主题: Re: [chrony-users] ipV4 and ipV6
On Sat, Nov 26, 2022 at 06:29:55AM +0000, chengyechun wrote:
Hi all
When the chrony works in both IPv4 and IPv6 modes, for example, one client is configured with two servers, one server is iPv4 and the other is ipv6, and the NTS function is configured. I found that they were able to communicate, but the time source state was displayed as x, which was a bit odd since they didn't have a big time difference:
[cid:image001.png@01D901A3.8C0B2D20]
The output shows that the sources are off by ~1.1 seconds from each other, but the estimate of accuracy is only in hundreds of microseconds. Their intervals don't overlap, so they are marked as falsetickers.
The time difference between the two machines is 1.1s. One machine is fast and the other machine is slow. There is no overlap between the two machines. As a result, the synchronization is faulty. If cross-connections exist, the system displays whether the synchronization is successful or whether the difference needs to be kept within the precision range.
It looks like two servers configured with the local reference mode.
That cannot work.
Yes, the two hosts are configured with local stratum.
--
Miroslav Lichvar
--
To unsubscribe email chrony-users-request@xxxxxxxxxxxxxxxxxxxx
with "unsubscribe" in the subject.
For help email chrony-users-request@xxxxxxxxxxxxxxxxxxxx
with "help" in the subject.
Trouble? Email listmaster@xxxxxxxxxxxxxxxxxxxx.
N?叉??y??!?蚝谦卜??????r?+n碰???\ó"???Р骒r?z)????n7?Z+?izf??????????觎??????'售???????+????ウ)????n7?:韫?f???X???f???贶?'售???????+