Re: [chrony-users] repeating "Can't synchronise: no selectable sources" log msgs ... but sources _are_ selected, and chrony _is_ sync'd. (mis)config or bug? |
[ Thread Index |
Date Index
| More chrony.tuxfamily.org/chrony-users Archives
]
- To: chrony-users@xxxxxxxxxxxxxxxxxxxx
- Subject: Re: [chrony-users] repeating "Can't synchronise: no selectable sources" log msgs ... but sources _are_ selected, and chrony _is_ sync'd. (mis)config or bug?
- From: Miroslav Lichvar <mlichvar@xxxxxxxxxx>
- Date: Mon, 12 Oct 2020 10:06:13 +0200
- Authentication-results: relay.mimecast.com; auth=pass smtp.auth=CUSA124A263 smtp.mailfrom=mlichvar@xxxxxxxxxx
- Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=redhat.com; s=mimecast20190719; t=1602489979; h=from:from:reply-to:subject:subject:date:date:message-id:message-id: to:to:cc:mime-version:mime-version:content-type:content-type: in-reply-to:in-reply-to:references:references; bh=Gsqd/eg4zExg/VQxQoUWImv8qtO/gHyTqfABQBVMzco=; b=ShtWFbWf8oXOXC9zPAU+bt8WI0RyL9mPcqx+ueK/pzltZdjz6X4YX4O8j59Hy8kZsSKIcd RIsbtCU0Y+8EwSug3w1CKJ6gN+NOqf8jdhAxeo0QD200zicj2x0Ocey2uNg5Mc00ZYsLv9 mbcny1MJHOpJ4nt9Akqqwmxnd0V3BzI=
On Fri, Oct 09, 2020 at 12:35:36PM -0700, PGNet Dev wrote:
> Oct 09 10:43:36 svr03.example.com chronyd[5922]: Forward time jump detected!
> Oct 09 10:43:36 svr03.example.com chronyd[5922]: Can't synchronise: no selectable sources
> Oct 09 10:43:38 svr03.example.com chronyd[5922]: Selected source 10.0.1.123
> Oct 09 11:23:49 svr03.example.com chronyd[5922]: Forward time jump detected!
> Oct 09 11:23:49 svr03.example.com chronyd[5922]: Can't synchronise: no selectable sources
> Oct 09 11:23:52 svr03.example.com chronyd[5922]: Selected source 10.0.1.123
> Oct 09 12:18:30 svr03.example.com chronyd[5922]: Forward time jump detected!
> Oct 09 12:18:30 svr03.example.com chronyd[5922]: Can't synchronise: no selectable sources
> Oct 09 12:18:33 svr03.example.com chronyd[5922]: Selected source 10.0.1.123
The issue here are the time jumps. When chronyd detects the clock has
jumped outside of its control, it will drop all measurements and start
from scratch. The "no selectable sources" is a result of that.
If it is a laptop that you frequently suspend and resume, this would
be expected. On a continously running machine it would not be. Is it a
virtual machine? Some have problems with their clock.
--