On Tue, Nov 28, 2017 at 08:52:18PM +0100, Rob Janssen wrote:
> Miroslav Lichvar wrote:
> > On Tue, Nov 28, 2017 at 07:20:10PM +0100, Rob Janssen wrote:
> > > The examples al refer to gps but this should work with refclock 8 (parse) too, right?
> > > I have a DCF77 receiver connected to a serial port that I used with ntpd and is not supported in chrony.
> > Yes, all drivers should work, at least in theory. I have not tested
> > the PARSE driver. If you try it, please let me know how it works. The
> > SOCK refclock probably should be configured with "poll 6 filter 1", as
> > there is only one sample per minute.
> >
>
> It logs this message regularly:
>
> ntp-refclock[13791]: PARSE receiver #0: local_receive: bad size (got 1 expected 480)
Thanks. This is helpful. The PARSE driver is different from the other
drivers in that it uses a "direct" input. It seems there were at least
two bugs in ntp-refclock related to that.
Could you please pull from git and try again?
--
Miroslav Lichvar
--