[chrony-dev] [PATCH 3/3] doc: Document "tai" refclock option |
[ Thread Index |
Date Index
| More chrony.tuxfamily.org/chrony-dev Archives
]
---
doc/chrony.conf.adoc | 9 +++++++++
1 file changed, 9 insertions(+)
diff --git a/doc/chrony.conf.adoc b/doc/chrony.conf.adoc
index 5c85959..55d23e1 100644
--- a/doc/chrony.conf.adoc
+++ b/doc/chrony.conf.adoc
@@ -552,6 +552,15 @@ Set the minimum number of samples kept for this source. This overrides the
*maxsamples* _samples_:::
Set the maximum number of samples kept for this source. This overrides the
<<maxsamples,*maxsamples*>> directive.
+*tai* _tai_:::
+This option can be set to indicate that the time on the given
+reference clock is kept in TAI and that chrony should attempt to apply
+the current TAI-UTC offset to samples taken from this refclock. To
+use this, the *leapsectz* directive must be used as chrony uses the
+timezone files to compute the current TAI-UTC offset. If the
+*leapsectz* directive is not in use, a warning will be logged and no
+offset will be applied. This option does not make sense if the given
+refclock is only being used for PPS input.
[[manual]]*manual*::
The *manual* directive enables support at run-time for the
--
2.13.5
--
To unsubscribe email chrony-dev-request@xxxxxxxxxxxxxxxxxxxx with "unsubscribe" in the subject.