Re: [chrony-users] firewalling chrony

[ Thread Index | Date Index | More chrony.tuxfamily.org/chrony-users Archives ]


Op 28/02/2014 om 13:17:10 +0100, schreef Miroslav Lichvar:
> On Thu, Feb 27, 2014 at 11:16:56AM +0100, Leo Baltus wrote:
> > One thing though, when running two instances the 'local stratum'
> > instance no longer get upstream information like leap seconds, how
> > bad is that?
> 
> Beside missing information about leap seconds, the root dispersion and
> root delay are reset to zero. A client could prefer this source over
> better sources (use a high local stratum to avoid that), or it could
> disagree with other sources and cause problem in the source selection
> with the "no majority" message or be marked as a falseticker. 
> 

That looks bad enough for me not to go this way.

I'll cowardly wait for the 'separate sockets for each configured server'
patch as I don't feel confident enough to do it myself.

Thanks for your insight.

-- 
Leo Baltus, internetbeheerder
NPO ICT Internet Services
Bart de Graaffweg 2, 1217 ZL Hilversum
servicedesk@xxxxxxxxx, 035-6773555

-- 
To unsubscribe email chrony-users-request@xxxxxxxxxxxxxxxxxxxx 
with "unsubscribe" in the subject.
For help email chrony-users-request@xxxxxxxxxxxxxxxxxxxx 
with "help" in the subject.
Trouble?  Email listmaster@xxxxxxxxxxxxxxxxxxxx.


Mail converted by MHonArc 2.6.19+ http://listengine.tuxfamily.org/